Evil_TTL> show | s

Stacking

Category:Cisco Systems -> Routing and Switching

A little practice with stacking mechanics on 3750 Catalyst switches based on the Cisco article http://www.cisco.com/en/US/products/hw/switches/ps5023/products_configuration_example09186a00807811ad.shtml

Switch#sh switch
Switch/Stack Mac Address 0014.1c9c.4880
                                           H
/W   Current
Switch#  Role   Mac Address     Priority Version  State
----------------------------------------------------------
*
2       Master 0014.1c9c.4880     1      0       Ready
 3       Member 0014.1c9c.5c00     1      0       Ready



Switch#conf t
Switch(config)#switch 2 ?
  
priority   Set the priority of the specified switch
  
provision  Configure Switch provision offline config
  renumber   Renumber the specified 
switch number

Switch(config)#switch 2 ren
Switch(config)#switch 2 renumber ?
  
<1-9>  New switch number

Switch(config)#switch 2 renumber 1
WARNINGChanging the switch number may result in a
configuration change 
for that switch.
The interface configuration associated with the old switch
number will remain as a provisioned configuration.
Do 
you want to continue?[confirm]
Changing 
Switch Number 2 to Switch Number 1
New Switch Number will be effective after next reboot

Switch(config)#do reload

Switch#sh switch
Switch/Stack Mac Address 0014.1c9c.4880
                                           H
/W   Current
Switch#  Role   Mac Address     Priority Version  State
----------------------------------------------------------
*
1       Master 0014.1c9c.4880     1      0       Ready
 2       Member 0014.1c9c.5c00     1      0       Ready
 3       Member 0000.0000.0000     0      0       Provisioned



Switch#conf t
Switch(config)#no switch 3 provision
Switch#sh switch
Switch/Stack Mac Address 0014.1c9c.4880
                                           H
/W   Current
Switch#  Role   Mac Address     Priority Version  State
----------------------------------------------------------
*
1       Master 0014.1c9c.4880     1      0       Ready
 2       Member 0014.1c9c.5c00     1      0       Ready



Switch#conf t
Switch(config)#switch 1 priority 5
Changing the Switch Priority of Switch Number 1 to 5
Do you want to continue?[confirm]
New Priority has been set successfully

Switch(config)#^Z
Switch#sh switch
Switch/Stack Mac Address 0014.1c9c.4880
                                           H
/W   Current
Switch#  Role   Mac Address     Priority Version  State
----------------------------------------------------------
*
1       Master 0014.1c9c.4880     5      0       Ready
 2       Member 0014.1c9c.5c00     1      0       Ready



Switch

Stack member interpretation reminder:

AUSYD****** uptime is 1 year31 weeks10 hours35 minutes
System returned to ROM by power
-on
System restarted at 03
:27:01 AEST Sun May 12 2013
System image file is 
"flash:/c3750-i5-mz.122-20.SE1.bin"

//Master switch (02) info down

cisco WS-C3750G-12S (PowerPC405processor (revision X0with 118784K/12280K bytes of memory.
Processor board ID FDO1412X2**
Last reset from power-on
Bridging software
.
37 Virtual Ethernet/IEEE 802.3  interface(s)
24 Gigabit Ethernet/IEEE 802.3 interface(s)
The password-recovery mechanism is enabled.

512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address       28:93:FE:85:**:**
Motherboard assembly number     73-9678-**
Power supply part number        341-0048-**
Motherboard serial number       FDO14121D**
Power supply serial number      NONE
Model revision number           
X0
Motherboard revision number     
A0
Model number                    
WS-C3750G-12S-E
System serial number            
FDO1412X2**
Top Assembly Part Number        800-26634-**
Top Assembly Revision Number    A0
Version ID                      
V14
CLEI Code Number                
COMA410B**
Hardware Board Revision Number  0x06

//Master switch (02) info up

//Stack info down

Switch   Ports  Model              SW Version              SW Image
------   -----  -----              ----------              ----------
     
1   12     WS-C3750G-12S      12.2(20)SE1             C3750-I5-M
*    2   12     WS-C3750G-12S      12.2(20)SE1             C3750-I5-M

//Stack info up

//Stack member switch 01 info down

Switch 01
---------
Switch 
Uptime                   1 year31 weeks9 hours39 minutes
Base ethernet MAC Address       
00:25:83:86:**:**
Motherboard assembly number     73-9678-**
Power supply part number        341-0048-**
Motherboard serial number       FDO131808**
Power supply serial number      LIT130907**
Model revision number           V0
Motherboard revision number     
B0
Model number                    
WS-C3750G-12S-E
System serial number            
FDO1318X0**
Top assembly part number        800-26634-**
Top assembly revision number    F0
Version ID                      
V14
CLEI Code Number                
COMA410B**

Configuration register is 0xF

//Stack member switch 01 info up 

Check flash on switch 01:

AUSYD*****#sh flash:

Directory of flash:/

   
82  -rwx     4958705   Mar 1 1993 11:04:46 +11:00  c3750-i5-mz.122-20.SE1.bin
  506  
-rwx         108   Mar 1 1993 11:07:04 +11:00  info
  507  drwx          64   Mar 1 1993 11
:05:33 +11:00  update
  508  
-rwx      262144   Mar 1 1993 11:07:21 +11:00  loader_bs.img
   83  
-rwx       33317   Sep 5 2014 16:43:31 +10:00  config.text
   84  
-rwx        7240   May 8 2014 10:37:51 +10:00  vlan.dat
   86  
-rwx          27   Sep 5 2014 16:43:31 +10:00  private-config.text

15998976 bytes total 
(843776 bytes free

Check flash on switch 02:

AUSYD*****#sh flash2:

Directory of flash:/

   
82  -rwx     4958705   Mar 1 1993 11:04:46 +11:00  c3750-i5-mz.122-20.SE1.bin
  506  
-rwx         108   Mar 1 1993 11:07:04 +11:00  info
  507  drwx          64   Mar 1 1993 11
:05:33 +11:00  update
  508  
-rwx      262144   Mar 1 1993 11:07:21 +11:00  loader_bs.img
   83  
-rwx       33317   Sep 5 2014 16:43:31 +10:00  config.text
   84  
-rwx        7240   May 8 2014 10:37:51 +10:00  vlan.dat
   86  
-rwx          27   Sep 5 2014 16:43:31 +10:00  private-config.text

15998976 bytes total 
(843776 bytes free

Copy the .bin image from the TFTP server to the Flash file system of both switches:

Switch#copy tftp: flash:
Address or name of remote host [172.22.1.165]?
Source filename [c3750-advipservicesk9-mz.122-25.SEE2]c3750-advipservicesk9-
.122-25.SEE2.bin
Destination filename [c3750
-advipservicesk9-mz.122-25.SEE2.bin]?
Accessing tftp://172.22.1.165/c3750-advipservicesk9-mz.122-25.SEE2.bin...
Loading c3750-advipservicesk9-mz.122-25.SEE2.bin from 172.22.1.165 (via Vlan1)
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!


!--- 
Output is truncated.


[OK 8172194 bytes]

8172194 bytes copied in 203.718 secs 
(40115 bytes/sec)


Switch
#copy tftp: flash2:
Address or name of remote host [172.22.1.165]?
Source filename [c3750-advipservicesk9-mz.122-25.SEE2.bin]?
Destination filename [c3750-advipservicesk9-mz.122-25.SEE2.bin]?
Accessing tftp://172.22.1.165/c3750-advipservicesk9-mz.122-25.SEE2.bin...
Loading c3750-advipservicesk9-mz.122-25.SEE2.bin from 172.22.1.165 (via Vlan1):
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!


!--- 
Output is truncated.


[OK 8172194 bytes]

8172194 bytes copied in 186.655 secs 
(43782 bytes/sec

Configure the boot variable to boot the switch with the newly copied IOS:

Switch(config)#boot system switch all flash:/
c3750-advipservicesk9-mz.122-25.SEE2.bin
Switch(config)#exit
Switch#write memory 

Verify the boot variable:

Switch#show boot
BOOT path-list      : flash:/c3750-advipservicesk9-mz.122-25.SEE2.bin

!--- Master switch.

Config file         flash:/config.text
Private Config file flash:/private-config.text
Enable 
Break        : no
Manual Boot         
no
HELPER path
-list    :
Auto upgrade        yes
-------------------
Switch 
1

!--- Member switch.

-------------------
BOOT path-list      : flash:/c3750-advipservicesk9-mz.122-25.SEE2.bin
Config file         
flash:/config.text
Private Config file flash:/private-config.text
Enable 
Break        : no
Manual Boot         
no
HELPER path
-list    :

Auto upgrade        no 

Reload the switch and verify that the switch runs the new Cisco IOS software version after the reload:

!--- Reload the switch.

Switch
#reload
Proceed with reload[confirm]


!--- Verify the Cisco IOS software version of the switch after the reload.


Switch
#show version
Cisco IOS SoftwareC3750 Software (C3750-ADVIPSERVICESK9-M), Version 12.2(25)SE
E2
RELEASE SOFTWARE (fc1)
Copyright (c1986-2006 by Cisco SystemsInc.
Compiled Fri 28-Jul-06 12:55 by yenanh
Image text
-base0x00003000data-base0x01256754 
By privilege15